beautypg.com

Lap pad calibration & set-up, Step 3: general setup continued – Liquid Controls LCR Setup & Operation User Manual

Page 12

background image

12

PRESET^

Available preset options include NET, BOTH, GROSS, and NONE. Selecting NONE will disable pre-

setting. Presetting NET, GROSS, or BOTH is allowed. Press ENTER and the cursor will drop to the

bottom line. Use LLLLL to scroll through the available preset options. When the desired option is displayed,

press ENTER and the cursor will move to the top line.

Press LLLLL and the cursor will move to:

PRESET TYPE^

There are four preset types:

CLEAR

Resets the preset values to 0 after the current delivery is ended.

RETAIN

Maintains the preset values to be used again on the next delivery.

MULTIPLE

Allows more than one preset to be run before a delivery ticket is printed. Printing must be

initiated by a PRINT command.

INVENTORY

Maintains the remaining preset amount between deliveries (i. e. indicates the remaining vol-

ume in the vehicle tank).

Press ENTER and the cursor will drop to the bottom line. Use LLLLL to scroll through the four options.

When the desired choice is displayed, press ENTER and the cursor will move to the top line.

Press LLLLL and the cursor will move to:

PULSE OUTPUT EDGE^

This feature allows you to synchronize the calibrated pulse output waveform with the requirements of

an external system that uses that LCR signal. There are two choices: RISING or FALLING. (Some

counters increment on rising, others on falling pulse edges. Refer to equipment technical manual to

determine the specific requirements of your connected equipment). Press ENTER and the cursor will

drop to the bottom line. Use LLLLL to scroll between the two choices. When the desired choice is displayed,

press ENTER and the cursor will move to the top line.

Press LLLLL and the cursor will move to:

Lap Pad Calibration & Set-Up

STEP 3: GENERAL SETUP CONTINUED

NO-FLOW TIMER CONTINUED

Press ENTER and the cursor will drop to the bottom line. Enter the desired NO-FLOW TIMER value

inseconds. Press ENTER and the cursor will move to the top line.

Press LLLLL and the cursor will move to:

PULSE OUTPUT EDGE^
RISING

PRESET TYPE^
CLEAR

PRESET^
GROSS

General Setup - Screen 3