beautypg.com

Basic operation without a lap pad, Printing diagnostic/calibration tickets – Liquid Controls LCR Setup & Operation User Manual

Page 37

background image

37

Basic Operation without a Lap Pad

DELIVERY & SELECTIONS MENU CONTINUED
PRINT Position (Product #/Totalizer) Continued

A shift ticket is printed when the Selector Switch is placed in the SHIFT PRINT Position for more than 2 seconds and a

printer is loaded with paper and available to print the ticket. (NOTE: If the Selector Switch is turned to SHIFT PRINT

and then out of SHIFT PRINT in less than 2 seconds, a Diagnostic/Calibration Information ticket is printed). Delivery
Total

is the initial display. The display will update every 15.625 ms.

Press SELECT to advance to Product Number Display:

The current active Product Number is displayed. If a delivery is not active, the digit will be flashing, indicating

that it can be changed. If the display is NOT flashing, it cannot be changed. Press

INCREASE

to scroll through

the options. These options are Prod 1, Prod 2, Prod 3, or Prod 4, depending on the number of product s

programmed during calibration. When the desired option has been chosen, press SELECT.

The display will advance to:

This displays the five most significant digits of the GROSS or NET Shift totalizer. Press INCREASE to return

to the Product Number display. Press SELECT to advance to:

Printing Diagnostic/Calibration Tickets

If a delivery was terminated due to a pulser failure, temperature probe failure or other fault, the last line on the delivery

ticket will read, "*FAULT: PRINT DIAGNOSTICS TICKET*".

A Diagnostic Ticket is printed when the Selector Switch is turned to the

SHIFT PRINT

Position for less than two

seconds. This ticket cont ains the same information found on the calibration ticket that print s when the Calibration

Mode is exited, but does not increment the calibration number or require a Weights & Measures seal to be broken.

This allows the operator to spot check the calibration of the register and/or diagnose problems with the unit.

The ticket

will show any problems on the last line to assist in troubleshooting the problem.

This displays the five least significant digits of the GROSS or NET Shift totalizer. The shift totalizer is a combination

of these two screens. The total in this example is “543,216,789.0” unit s. Press INCREASE to return to the

previous totalizer display. Press SELECT to return to Delivery Total.

P r o d 1

L6789.0

H 1 2 3 4 5