7.7.2. Kv value

Orifice
DN
Body
connection
[mm]

Valve size

Actuator

Kv value water [m³/h] for
diaphragm material

Designation EPDM,

FKM

PFA

10

3/8"

RV50

0.8

0.7

15

1/2"

RV50

2.5

2

20

3/4"

RV50

3.5

3.3

25

1"

RV70

10

9

40

1 1/2"

RV110

27

22

50

2"

RV110

35

27

Tab. 3: Kv value

All Kv values measured on valves with connections according
to ASME BPE.

8.

asseMBly

8.1.

safety instructions

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

Warning!

risk of injury from improper assembly.

▶ Installation must only be carried out by authorized technicians and

with the appropriate tools.

risk of injury from unintentional activation of the system and
uncontrolled restart.

▶ Secure system from unintentional activation.

▶ Following assembly, ensure a controlled restart.

8.2.

Before installation

• Before connecting the valve, ensure the pipelines are flush.
• Pay attention to the flow direction.