If you need to use your own Software Control program from a

PC or automation, the device allows communication through an

ASCII code protocol. All commands can be found on the CD-Rom

shipped with the

Eikos LE in the “External Programming” file.

Information can also be found in the “Progrmmer’s Guide” on

certain media or documentation (website, CD-Rom,...).

All Analog Way products equipped with an RS232 input are

compatible with Crestron, AMX, Medialon, and most major

control systems. TCP/IP control ports are also available on

most Analog Way products, as standard or as options.

To control an

Eikos LE product with an External Remote

Controller (PC Software Control - Touch Pad Controller…)

follow the indications below:

1. First establish an RS-232 communication between the

Remote Control Software and the

Eikos LE, in order to

setup the LAN parameters of the product.

2. In the “Control” - “Eikos LE LAN Setup” menu, configure

the connection of the

Eikos LE product in UDP mode and

setup the Local and Remote Addresses as well as the Local

and Remote Ports in concordance with your Network.

3. Configure the TCP/IP address of your External Remote

Controller.

In example: 192.168.000.001

4. Setup the UDP connection of your External Remote

Controller in concordance with your Network.

In example on the Remote Software in the “Control” -

“RS232/LAN Setup” - “LAN/Setup” menu :

5. Setup the LAN parameters in UDP mode in the “Console”

- “LAN Setup” menu.

In example: RK Address:

192.168.000.002

Remote

Address: 192.168.000.010

Gateway

Address:

192.168.000.001

RK

Port:

10500

Remote

Port:

10500

Netmask:

255.255.255.000

6. Select the LAN communication port in the remote controller

console - “RS232/LAN port” menu.

7. You can now control your

Eikos LE product with an External

Remote Controller.

7-3. EXTERNAL PROGRAMMING

82