746-257-B2-001, Rev. B (01/2014)

The CPE Communications Module IP can be assigned its IP, Subnet Mask and Gateway Addresses either

via DHCP (default) or manually, either through the web page or via the below SNMP settings:

MIB Parameter

Object ID

Description

Value

atiMgmtSysMonitoringCpeStaticMode

1.3.6.1.4.1.926.1.3.2.2.5.2.1.0

Method by which the CPE

acquires its IP address.

1=DHCP

2=Static

atiMgmtSysMonitoringCpeStaticAddress

1.3.6.1.4.1.926.1.3.2.2.5.2.2.0

When the IP address is static,

this is the IP address to which

the CPE will respond.

0.0.0.0 (default)

atiMgmtSysMonitoringCpeStaticMask

1.3.6.1.4.1.926.1.3.2.2.5.2.3.0

When the CPE IP address is

static, this is the subnet mask.

0.0.0.0 (default)

atiMgmtSysMonitoringCpeStaticGateway

1.3.6.1.4.1.926.1.3.2.2.5.2.4.0

When the IP address is static,

this is the IP address of the

gateway.

0.0.0.0 (default)

11.0 Dual IP Mode

11.3 Configuring Dual IP Mode

To switch the IDH4 Series Communications Module from Single to Dual IP mode the

atiMgmtSnmpSnmpCPEAccess parameter of the Alpha MIB will need to be enabled. The Dual IP enable

setting can be set through the DOCSIS Configuration File, the IDH4 Setup File (atidoc03.cfg), the

Provisioning Mode via the Communications Web page or remotely using SNMP by setting the following

Alpha MIB:

MIB Parameter

Object ID

Description

Value

atiMgmtSnmpSnmpCPEAccess

1.3.6.1.4.1.926.1.3.1.3.6.0

Enables/Disables the

CPE Interface

1=Disabled (Single IP)

2=Enabled (Dual IP)

Table 11-2, Enabling Dual IP mode

Table 11-3, CPE Communications Module IP Settings

After configuring the Static settings the Communications Module must be reset in order for the settings to

take effect.