0 start up and verification, 3 system status indicators and reset button, 1 detailed led descriptions – Alpha Technologies AlphaNet IDH4 for XM2 and XM2-300HP Series - Technical Manual User Manual

Page 68

background image

68

746-257-B2-001, Rev. B (01/2014)

Fig. 9-3, LED Functionality and Indications

9.3

System Status Indicators and Reset button

As viewed from the front of the unit, the IDH4 Series utilizes light emitting diodes (LEDs) to indicate

system status. During system startup, the LEDs will first blink momentarily then indicate the current status

of a variety of parameters on the IDH4 Series transponder. The LEDs indicate alarms, RF power level

status, battery string connectivity and communications activity with the network. A description of each LED

follows.

LED

Status

Behavior

Indication

ALM/RDY: Alarm and Ready

N/A

OFF

No power or malfunctioning IDH4 Series

GRN

ON

Reset of the IDH4 Series is in process

Steady Blinking

Normal operation

RED

Blinking more OFF than ON

Minor Alarm SCTE-HMS configured

Blinking more ON than OFF

Major Alarm SCTE-HMS configured

REG: Upstream ranging and

registration lock.

GRN

OFF

No power, upstream frequency undetermined

OFF / ON

Power on, downstream locked, upstream frequency ranging,

DHCP request in progress

ON

CMTS registration completed

DS: Downstream RF Carrier

detection and lock.

GRN

OFF

No power / downstream carrier

OFF / ON

Power on, downstream carrier frequency searching

ON

Downstream carrier lock

ACT: CPE Activity status

GRN

OFF

No Ethernet communications activity

OFF/ON

Momentary flashes while CPE communications ongoing via

the Ethernet craft port

LNK: CPE Link status

GRN

OFF

No Ethernet link

ON

Link on Ethernet Craft port

RF Rx/Tx Power Level

Indicator

TRI

OFF

No RF detected

Blue

Rx/Tx Power at a warning level as set within the SCTE-HMS

Property Table

Green

Rx/Tx RF Power level within tolerance

Red

Rx/Tx Power at an alert level as set within the SCTE-HMS

Property Table

COM: AlphaBus

communications.

GRN

OFF

No AlphaBus Communications

OFF/ON

Momentary flashes - AlphaBus Port communications active

BATT A/B

GRN

ON/OFF

ON (steady) if battery string(s) connected correctly

BATT C/D

GRN

ON/OFF

ON (steady) if battery string(s) connected correctly

ALM/RDY
REG

ACT
LNK

RF

BATT A/B

BATT C/D

COM

9.0 Start Up and Verification

9.3.1 Detailed LED Descriptions

After power is applied or a reset occurs, all LED's will flash in certain patterns indicating the cable

modem chipset is starting or restarting. Once it is ready it will begin the DOCSIS requirement of

searching for the downstream frequency lock and the LED's will follow the detailed descriptions

below.
ALM/RDY - Alarm/Ready
The ALM/RDY - During normal operation, this LED blinks GREEN, indicating a heartbeat pulse

from the processor. The frequency of flashing by this LED provides a visual alert for power supply

discrete major and minor alarms, if configured in the property and discrete property tables of

the SCTE-HMS MIB. The ALM LED (RED) is factory defaulted OFF. Refer to Section 6.3 for

information on configuring the IDH4 Series for active monitoring and alarming. If an event triggers

an HMS alarm, the ALM/RDY LED blinks RED according to the alarm type until the alarm has

been resolved. For a minor alarm, the frequency of flashing (RED) will be more OFF than ON and

for a major alarm the frequency of flashing will be (RED) more ON than OFF. If there are multiple

active alarms, including one or more major alarms with one or more minor alarms, the major

alarm will take precedence in terms of the indication.

DS