0 start up and verification – Alpha Technologies AlphaNet IDH4 for XM2 and XM2-300HP Series - Technical Manual User Manual
Page 69

69
746-257-B2-001, Rev. B (01/2014)
9.3.1 Detailed LED Descriptions
REG - CM Registration
Once a downstream channel has been negotiated between the CM and CMTS, the modem
attempts to register with the DHCP server and obtain the configuration file. This LED flashes
while the process takes place. Once the registration is complete, the LED will remain on solid.
This is the best indication that the IDH4 Series is communicating with the CMTS in the headend.
DS - Downstream Communication
This LED indicates the state of the CM's attempt to gain a downstream signal. This process may
take several seconds, depending on how long it takes the CM to locate a carrier signal and lock
onto a channel. The LED flashes while searching for the downstream DOCSIS channel and is on
solid when the downstream channel is locked.
ACT - CPE Activity
The CPE activity LED flashes to indicate that data is being transmitted or received between the
IDH4 Series and a network device.
LNK - Network Communication Status
The Ethernet link LED remains ON when there is an active connection on the Ethernet port (e.g.,
a computer is connected for local diagnostics).
Rx/Tx Power
The Rx/Tx PWR LEDs provide the installer a quick verification of the modem transmit (Tx) and
receive (Rx) RF power levels. The Rx/Tx PWR LED will illuminate “green” when both the cable
modem Tx and cable modem Rx RF power levels are within the range as specified in the SCTE-
HMS PropertyTable. The LED indicator illuminates “blue” when Rx and/or Tx levels are within
the “warning” range as specified by the SCTE-HMS PropertyTable. The LED indicator illuminates
“red” when Rx and/or Tx levels are outside the range as specified by the SCTE-HMS Property-
Table.
Refer to the following table for default ranges in the SCTE-HMS PropertyTable:
9.0 Start Up and Verification
Parameter
alarm Enable
HiHi
Hi
Lo
LoLo
Deadband
Rx
docsIfDownChannelPower
(OID:1.3.6.1.2.1.10.127.1.1.1.1.6)
00
(0F*)
150
100
-100
-150
15
Tx
docsIfCmStatusTxPower
(OID:1.3.6.1.2.1.10.127.1.2.2.1.3)
00
(0C*)
550
500
00
00
15
* Values in ( ) denote behavior of the Rx/TX LED if alarmEnable bits are set to ‘00’.
By default, alarmEnable is set to 00 (disabled) to prevent unwanted SNMP traps but the LED
behavior will function as if the alarmEnable were set to the values in the above table. If the alarm
Enable bits are set to anything other than 00 the LEDs will then follow the behavior of the desired
enable bit setting.
The above default values translate into the following Rx/Tx Power LED color ranges:
LED Color
Rx Range (dBmV)
Tx Range (dBmV)
Green
+10 to -10
0 to +50
Blue
+15 to +10 and -10 to -15
+50 to +55
Red
>+15 and <-15
>+55