4.0 Web Interface
4.3 Navigating the Web Page
4.3.1 Web Interface Security Levels
Within the IDH4 Series transponder are two levels of function-specific security. General
operations are set at Level 1 and configuration-related functions are set at Level 2.
Default User ID and Passwords are shown in the figure below.
Fig. 4-8, IDH4 Series Transponder Security Levels
IDH4 Series Web Page Security
OID
Function
Value
1.3.6.1.4.1.4413.2.2.2.1.1.3.3.0
Level 1 User Name
Alpha
1.3.6.1.4.1.4413.2.2.2.1.1.3.4.0
Level 1 Security Password
AlphaGet
1.3.6.1.4.1.4413.2.2.2.1.1.3.1.0
Level 2 User Name
Alpha
1.3.6.1.4.1.4413.2.2.2.1.1.3.2.0
Level 2 Security Password
AlphaSet
Web Page
Function
Security Level
General
System Name, System Contact, System Location,
Common Logical ID
1
Power Supply Self Test
1
Generator Self Test
1
Advanced Communications
Reset Transponder
1
Provisioning Mode - Single IP or Dual IP
2
Configure Static IP Address
2
Configure Proprietary Trap Addresses
2
Power Supply Self Test
1
Advanced Power Supply
Configure/Save
2
Reset Output 1/2
2
Advanced Generator
Generator Self Test
1
Reset Latched Alarms
1
Modem Log [Event Log]
Reset Log
1
Advanced I/O
Tamper Switch Polarity
1
Enclosure Heater/Cooler Installed
1
4.4
Verifying Communication Parameters
Click the
General menu of the web page to display common communication settings and values. Click
the
Advanced Communication menu to view additional communication parameters.
Fig. 4-9, Communication Parameters
(data values shown for illustration purposes only)