Section 5 Component Testing and Adjustment

Use a feeler gauge to check gap between ignition trigger
coil and flywheel. See Figure 5-14 and Figure 5-15.
Verify that the gap is set to 1.02 mm (0.040 in.).

1. Ignition trigger

1

TP6092

Figure 5-14 Ignition Trigger

1. Ignition trigger

1

TP6092

Figure 5-15 Ignition Trigger Adjustment

5.5.2

Ignition Module

Use an ohmmeter to measure the resistances across
the ignition module terminals.

See Figure 5-16 and

Figure 5-17.

The ignition module part number is

stamped on the back of the module. If the measured
resistances do not match those shown in Figure 5-17,
replace the module.

Note: The ignition module must be matched with the

appropriate trigger coil. See Section 5.5.1 for
information.

GM14140B-V

2

1. Ground connection
2. Ignition module
3. Ignition coil

3

1

Figure 5-16 Ignition Components

Terminals

Ohmmeter Indication

Part Number 278903

W--G

10 kOhms

B--Ground

850 ohms

C--Ground

Diode check: Open circuit in one direction,
approximately 2.7 mOhms with the test leads
reversed.

Part Number GM23591

W--G

450 Ohms

B--Ground

850 ohms

C--Ground

Diode check: Open circuit in one direction,
approximately 2.7 mOhms with the test leads
reversed.

Figure 5-17 Ignition Module Resistances

Apply a thin coating of thermal compound between the
mounting pad and the module to ensure good heat
transfer. Connect the ground wire to the system ground.