beautypg.com

Alpha Technologies AlphaGen 3.5_5.0kW Kohler COM5 User Manual

Page 25

background image

TP-6482 8/06

25

Section 3 Scheduled Maintenance

M-337000B-B

1

4

5

2

3

1. Oil check, fill
2. Exhaust pipe connection
3. Oil cooler

4. Oil filter
5. Oil drain

Figure 3-5

Lubrication System, Specification Numbers GM14140-GA1 and above

3.4.2

Engine Oil Recommendation

Kohler Co. recommends API (American Petroleum
Institute) Service Class SG, SH, or SJ 5W-30 synthetic
oil. Synthetic oil oxidizes and thickens less than other
oils and leaves fewer deposits on the engine intake
valves and pistons.

3.4.3

Oil Change Procedure

Allow the oil to cool to a safe temperature before
changing.

1. Follow the instructions in Section 3.3 to access the

generator set oil drain plug, filter, and fill tube. See
Figure 3-4 and Figure 3-5.

2. Drain the oil.

a. Place an oil collection container below the oil

drain and remove the oil drain plug.

b. Allow the engine oil to drain completely.

c. Replace the oil drain plug.

3. Replace the oil filter.

a. Place an oil collection container below the oil

filter.

b. Remove

the

oil

filter

by

rotating

it

counterclockwise with an oil filter wrench.

c. Clean the gasket sealing surface of the oil filter

adapter.

d. Apply a light coat of clean oil to the rubber seal

of the new oil filter.

e. Install the new oil filter following the instructions

provided with the filter. Hand-tighten the filter.

Note: Dispose of all waste materials (engine

oil, fuel, filter, etc.) in an environmentally
safe manner.

4. Fill with oil.

a. Remove the oil fill cap and fill the engine to the F

mark on the dipstick. The engine oil capacity is
2.0 L (2.1 qt.).

See Section 3.4.2 for oil

selection.

b. Reinstall the dipstick and the oil fill cap.

5. Slide the generator set back into the cabinet and

reconnect the exhaust pipe and wiring harnesses
as described in Section 3.3. Do not replace the
compartment front panel.