Alpha Technologies AlphaGen 3.5_5.0kW Kohler COM5 User Manual
Page 38

TP-6482 8/06
38
Section 4 General Troubleshooting
Is fuel solenoid
and wiring okay?
No
Yes
Is fuel pressure regulator okay?
Verify that output pressure to
engine is at zero—the engine
must draw gas from regulator.
No
Replace pressure regulator.
Yes
No
Yes
Lacks Power or Runs Erratically, continued
D
Adjust fuel
metering valve.*
Check the fuel adjustment using
an oxygen sensor. See Section
5.7. Is the fuel adjustment
correct?
* Adjusting the fuel system may void the emissions certification. Only trained and authorized service technicians should
adjust the fuel system. Use the test equipment specified in the test procedure in Section 5.7.
Check the throttle linkage.
See Section 5.4. Throttle
linkage binding?
Check carburetor. See the
engine service manual for
carburetor service
information.
Repair/replace ignition
components as needed.
Yes
Test the ignition system. See
Section 5.5. Ignition problem?
Repair throttle linkage.
Yes
Repair/replace faulty
components.
No
No
- AlphaCell GelCell Series (32 pages)
- FXM 650, 1100, 2000 UPS (96 pages)
- Cordex 48-1.2kW (68 pages)
- Radium MiniBay (57 pages)
- Fiber Backhaul Enclosure (FBE) (19 pages)
- FBE2322 Enclosure System (38 pages)
- FlexNet PMR, GMR Series (49 pages)
- Te25xh (38 pages)
- FlexNet MPS48-12M - Technical Manual (33 pages)
- FlexNet MPS48-12M - Quick Start Guide (2 pages)
- FlexNet ELPM 300-48D (25 pages)
- FlexNet FMPS (40 pages)
- FlexPoint AX Series (34 pages)
- FlexPoint FPR1207-F - Technical Manual (18 pages)
- FlexPoint FPR1207-F - Quick Start Guide (2 pages)
- AlphaGen PN-6x-T 7.5kW 48VDC - Installation and Operation Manual (79 pages)
- AlphaGen CE-3x2 5K-T 48Vdc (95 pages)
- AlphaGen PN-6x-T 7.5kW 48Vdc (95 pages)
- Security Bar Field For UPE-3, UPE-6, UPE-M3, UPE-M6, PN Series and CE Series (2 pages)
- AMPS80 HP (116 pages)
- 255A Bypass Switch (24 pages)
- AMP24 HP (108 pages)
- FXM350_Micro350 UPS (112 pages)
- CFR 600, CFR 600XT, CFR 1000 (70 pages)
- BPS Series Bypass Switch (36 pages)
- CFR Intelligent Interface Device (54 pages)
- CFR Redundant Control Unit (23 pages)
- CFR 5000, CFR 5000RM (88 pages)
- CFR 3000, CFR 3000RM (86 pages)
- CFR 1500, CFR 1500RM (83 pages)
- CFR 1500, CFR 2000, CFR 2500, CFR 3000 (76 pages)
- Continuity: 1000_2000_3000 (48 pages)
- Continuity Battery Pack (20 pages)
- Continuity: 6K_10K (52 pages)
- Micro, Micro XL, Micro XL3 UPS (99 pages)
- Micro Secure UPS (80 pages)
- Te17 (32 pages)
- Te45 (68 pages)
- Te41, 48V (76 pages)
- Te41, 24V (72 pages)
- Te43 (60 pages)
- AlphaGuard AG-CMT Installation (2 pages)
- AlphaGuard AG-CMT-3SC_4SC-P (2 pages)
- Digital Midtron DM-3200 AT (2 pages)