beautypg.com

Alpha Technologies AlphaGen 3.5_5.0kW Kohler COM5 User Manual

Page 38

background image

TP-6482 8/06

38

Section 4 General Troubleshooting

Is fuel solenoid
and wiring okay?

No

Yes

Is fuel pressure regulator okay?

Verify that output pressure to

engine is at zero—the engine

must draw gas from regulator.

No

Replace pressure regulator.

Yes

No

Yes

Lacks Power or Runs Erratically, continued

D

Adjust fuel

metering valve.*

Check the fuel adjustment using

an oxygen sensor. See Section

5.7. Is the fuel adjustment

correct?

* Adjusting the fuel system may void the emissions certification. Only trained and authorized service technicians should

adjust the fuel system. Use the test equipment specified in the test procedure in Section 5.7.

Check the throttle linkage.

See Section 5.4. Throttle

linkage binding?

Check carburetor. See the

engine service manual for

carburetor service

information.

Repair/replace ignition

components as needed.

Yes

Test the ignition system. See

Section 5.5. Ignition problem?

Repair throttle linkage.

Yes

Repair/replace faulty
components.

No

No