10 Display and setting elements
13
10.4.3 CON1
CON1 (C) jumper connection “FIT DISABLE TAMP”.
If you set the jumper on both contacts, you deactivate the wall removal
contact. (This may be helpful during programming.)
10.4.4 CON2
CON2 (D) jumper must be in the “-” position (factory setting).
10.4.5 DIP switch SW6
DIP switch SW6 (E) is factory-set as follows.
The individual switches of this 8-position DIP switch enable you to choose from the
following options. Switch positions 4/5/7/8 must remain in the factory settings to
guarantee correct functionality.
Switch
Options
Factory setting
“OFF”
position
“ON”
position
1 Supervision ON
Off On
2 Supervision
time
ON
Long
3 hours
Short
20 min
3 Jamming
detection
ON
Off On
4
OFF
5
ON
6
LED mode
OFF
Display on
Display off
7
OFF
8 Acoustic
signal
ON
Off On
10.4.6 CON3:
CON3 (F): This jumper is used to switch on the installer mode of the
FU8220 external siren.
(The installer mode is deactivated in the factory default setting.)
This mode is useful for changing the battery. You can open the housing
without the siren emitting any sound. The Secvest IP must also be in the
“training mode” to suppress e-mail notification. („System Æ Maintenance“)