9 Installation of the backup battery (backup power supply)

10



6. Fasten the 13.8 V cable and LAN cable to the appropriate tension relief using the

supplied cable clips.

7. Fix the housing to the wall.
8. Make sure the spring of the wall tamper switch (A) is positioned correctly.
9. Make the appropriate settings on the web server.
10. Train the wireless components.
11. After training, replace the housing cover and tighten the cover screw.

9. Installation of the backup battery (backup power supply)


1. Disconnect the alarm centre from the power

supply.

2. Connect the supplied cable for the battery to

the IP module.

Red is the positive terminal and black is the
negative terminal. See the installation section
for more details.

3. Connect the battery correctly.
4. Insert the battery into the appropriate battery

clip and close the housing. See the installation
section for more details.

Trained wireless components and
programming are not lost in the event of a
power failure.

BT2020