Installation – ABUS FUAA10021 Secvest IP Basic Set Operating instructions User Manual
Page 10

8 Installation
9
8. Installation
Key:
A) Wall tamper switch
B) Housing
screw
C) Fixing holes on base plate
D) Cable
opening
E) Tension relief (bar for fastening cable to cable clip)
Installation procedure:
1. Loosen the housing screw on the bottom narrow side and open the housing.
2. Using the back of the housing as a template, mark the drill holes (C).
Drill the holes for the fixing screws.
3. Guide the connection cable through the appropriate opening (D).
4. Connect the power supply to the terminal block with the correct polarity
(grey dashed wire is positive).
5. Connect the LAN cable (see following diagram).
A
B
C
C
E
D
13.8 V DC
(power supply unit)
Power supply for
optional BT2020
backup battery
IP