beautypg.com

ABUS AZ6302 Terxon GSM dialer User Manual

Page 82

background image

82

Call Active

The output is activated when the GSM dialer triggers and a dialling
procedure is started. The output is deactivated when all devices are
dialled or the call is cancelled.

Call Successful

The output is activated when the message is sent correctly and
deactivated when the device triggers again.

Call Fail

The output is activated when the message fails and deactivated when
the device triggers again.

Remote Control 1-4

These outputs can be activated and deactivated remotely over the
telephone.

Supply Low

The output is triggered when the power supply of the device falls
below 10.5 V DC.

Signal Low

The output is triggered when the GSM signal falls below the defined
level (see “Alarm states” for more details).

8.3.6.2 Configuring the outputs

5. Enter your user code. Scroll through the menu options using the

keys, or alternatively press

to display the “Outputs” menu point.

↑↓ ENT to select

Outputs


Confirm by pressing

. The following message is displayed:

Output 1.

6. Use the scroll keys

and confirm the output using

.

7. Use the scroll keys

and confirm using

in order to select

one of the output types detailed previously.

8. Press

to exit the menu.

8.3.7 Call

Routing

Under this menu option, you can define which contact addresses receive
messages (text or voice). For example, the alarm message A is transferred to