Control panel security lockout (executive mode), Rear panel resets, Performing soft resets – Extron Electronics MKP 2000 User Manual
Page 20: Loc ad, Local operation, cont’d

MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
Local Operation, cont’d
3-8
9
.
If necessary, use the Output button to toggle the connection
priority setting between primary and secondary.
10
.
When all addresses, octets, the host control setting, and the
priority settings are correct, press the Take button.
Host control port setting and pass-through communications
When the MKP is
•
Connected to a computer or control system via its Host
RS-232 port and
•
In pass-through mode,
the MKP redirects valid matrix switcher SIS commands that it
receives on its Host RS-232 port to its Switch RS-232 port.
When the MKP is
•
Connected to a computer or control system via its Host
RS-232 port and
•
In no pass-through mode,
the MKP acts on all valid MKP commands received. It does not
pass the command to its Switch RS-232 port.
When the MKP is
•
Selected as primary,
the MKP directly controls the matrix switcher via its
Switch RS-232 port or LAN port.
•
Selected as secondary,
the MKP controls the matrix switcher through connection
to the primary MKP’s IP address.
Control panel security lockout (executive mode)
The MKP 2000 provides the following three levels of front panel
security lockout (executive modes):
Panel Locked mode
— All front panel controls are locked.
Selections and setup cannot be performed from the front
panel.
User mode
— Front panel operation is limited to input and
output selection. The panel configuration, IP, and switcher
addressing functions are locked.
Administrator mode
(default) — All front panel controls are
available.
To step through the selections for the three executive modes,
1
.
Press and hold the 1, 3, Back, and Cancel buttons until the
LED window displays one of the following messages,
indicating the executive mode that has been set
(approximately 3 seconds).
•
Administrator mode
— The LED display flashes
LOC
, then Ad; then displays “. . . “.
•
User mode
— The LED display flashes LOC, then
Us
; then displays “. . .”.
•
Panel Locked mode
— The LED display shows LOC.
2
.
Repeat step 1 until the LED indicates the mode you want.
1
3
BACK
CANCEL
LOC
Ad
. . .
Simultaneously press
and hold these buttons.
The LED display flashes the
LOC, then Ad messages.
3
seconds
The “. . .” message
remains while the
front panel is
unlocked.
Figure 3-7 — Control panel lockout: switching to
Administrator mode
Rear Panel Resets
Performing soft resets
The remote control panel has three soft resets available that
restore various tiers of MKP settings to their defaults.
•
Events (mode 3) reset —
Restarts the communications
and control events.
•
IP system (mode 4) reset —
Resets most IP protocols to
their default settings.
IP system reset clears the Internet protocol (IP) settings,
but does not reset the target address, the host control
setting, the priority setting, or any user-loaded files.
•
Absolute (mode 5) reset —
Performs all of the system
reset functions and clears the MKP’s IP address to
192.168.254.253 and subnet mask to 255.255.0.0. This
function is identical to the
Esc
ZQQQ
SIS command.
See chapter 4, “SIS
™
Operation.”
3-9