SetOscan

Function

Sets the overscan or underscan factor required by the display devices.

Format

SetOscan=<horizontal overscan>,<vertical overscan>,0,0,0,0\r

Arguments

<horizontal overscan> and <vertical overscan> are specified as either a positive
number representing the amount of overscan or a negative number representing
the amount of underscan.

Typically the required overscan/underscan will be quoted as a percentage,
e.g. 8.5%. To obtain the value for this argument, multiply the percentage value
by 1024 then divide by 100.

Using the example of 8.5% will give 8.5Ч1024ч100 = 87.04.
Round the answer up or down to the nearest whole number, i.e. 87.

Example

SetOscan=87,87,0,0,0,0\r

Configures the outputs for 8.5% overscan horizontally and vertically. Values
derived from 8.5Ч1024ч100 = 87.04 (rounded to 87).

SetOscan=–90, –120,0,0,0,0\r

Configures the outputs for –8.8% underscan horizontally and –11.7% underscan
vertically. Values derived from –8.8Ч1024ч100 = –90.112 (rounded to –90) and
–11.7Ч1024ч100 = –119.808 (rounded to –120)