beautypg.com

Setadjust – Extron Electronics ImageStar HD User Manual

Page 83

background image

IMAGESTAR HD USER GUIDE

Appendix A: Control Protocol

I460GB issue 4

Page 83

SetAdjust

Function

Adjusts the contrast, brightness, clocking or positioning of the specified source
(applies to RGB Inputs 1 & 2 only)

Format

SetAdjust=<channel>,<parameter>,<adjustment>,0,0,0\r

Arguments

<channel> is the input channel number:

0 = Input 1 (RGB)
1 = Input 2 (RGB)


<parameter> defines which attribute of the source to adjust:

0 = contrast
1 = brightness
2 = horizontal start
3 = vertical start
4 = pixels per line
5 = clock phase

<adjustment> defines the amount of adjustment required and must be a number
between –32 and +32.

Examples

SetAdjust =0,0,-5,0,0,0\r

Decreases the contrast of input 1 by a factor of 5.

SetAdjust =1,3,10,0,0,0\r

Shifts the vertical start position of input 2 down by 10 pixels.