Mounting the ipcp 505, Ul rack mounting guidelines, Brief guidelines for mounting – Extron Electronics IPCP 505 User Guide User Manual

Page 16: Mount

background image

IPCP 505 • Hardware Features and Installation

10

Mounting the IPCP 505

Optional rack shelves are available for use with the IPCP.
Read the instructions
that come with the rack
shelf or mounting kit for
installation procedures.
The IPCP 505 includes
rubber feet so it can be
set on a table. If you are
going to mount the unit
to a rack shelf and these
feet were attached to the
enclosure, remove the
feet before mounting.

UL Rack Mounting Guidelines

The following

Underwriters Laboratories (UL)

guidelines pertain to the safe installation of

the IPCP 505 in a rack.

1.

Elevated operating ambient temperature — If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore, install the IPCP in an environment
compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified
by Extron.

2.

Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.

3.

Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.

4.

Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.

5.

Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as use of power strips).

Use 2 mounting holes
on opposite corners.

(2) 4-40 x 3/16"
Screws

NOTE:

Using screws longer

than 3/16" will damage the
unit and void the warranty.

1U Universal Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate