GEH-6405A Toolbox for an AVDV Series Drive
Chapter 4 Configuring an AVDV Series Drive
•
4-17
Take Motor Parameters
corresponds to the Take Motor par command in the
drive (keypad). This command must be issued after entering values into the “Mot
plate data” submenu in order to validate them and compute estimates for the
parameters in the “Motor parameter” submenu. Previous values in the “ Motor
Parameter” submenu are overwritten. This menu item may not be enabled for all
drive types.
Load Motor Parameters
corresponds to the Load Motor par command in the
drive (keypad). Choose 400 V or 460 V parameters.
Copy Motor Setup ( Setup 0, Setup 1)
copies the current motor parameters to
the alternate storage provided by either Setup 0 or Setup 1.
Motor Selection ( Setup 0, Setup 1)
causes the alternate motor parameter
values in either Setup 0 or Setup 1 to be copied to the active motor parameters.
Self-tune
activates the self-tune process where the drive and the motor perform
predefined tests to determine the best running conditions for the system.
Options Menu
The Options menu allows you to manage general options for toolbox operation.
Settings
allow you to set general toolbox options.
Privilege
sets the privilege level for a session.
Passwords
set the password for a privilege level.
Logout User
closes the current user from the current session and sets the privilege
level back to 0.