8.2.1 Troubleshooting 1…10 V

Lamp does not burn with 100 % luminous flux

The control line is not connected or not correctly connected to the

control unit, or the control unit is not a sufficiently good current sink
and, hence, cannot reduce the control voltage.

Check the wiring. Check that the control voltage is reduced while

dimming and, if necessary, install a parallel resistor in the control
line.

Also one or more control inputs may be pole reversed:

Disconnect control unit

Subdivide control circuit

Further subdivide control circuit

Lamp always burn at minimum brightness

+ and - connectors of the control line are reversed, or short circuit

in the control line.

Connect lines with correct polarity, check wiring

The lamp does not show the required luminous flux when
controlled with potentiometers or fixed resistors.

Potentiometers or resistors are wrongly dimensioned. Check the

values

Insufficient brightness along the lamp

Spacing of the reflector to the lamp is too small, capacitive dis-

charge currents occur.

Increase gap between the reflector and the lamp

Synchronous lamp flickering

Fault is outside the dimming system, e.g. N conductor disconnec-

tion, control voltage not OK

Check N conductor connection and control unit