beautypg.com

OSRAM QUICKTRONIC INTELLIGENT DIM CFL User Manual

Page 71

background image

70

QUICKTRONIC

®

INTELLIGENT DIM (1…10 V) for compact fluo-

rescent lamps
Ordering designation for each type of lamp: QTi-T/E…DIM
• Intelligent ECG with 1…10 V interface acc. to IEC 60929

OSRAM DULUX compact fluorescent lamps

®

T/E 18, 26, 32, 42 W

and OSRAM DULUX

®

T/E IN 26, 32, 42 (57) W (amalgam lamps)

unrestrictedly dimmable from 3 % to 100 %

Warm start of the lamp inside 0.6 seconds without switch-on
flash

Service life: 50,000 h at maximum thermal load (t

c

= 75 °C, max.

10 % failure)

Effective excess temperature protection of the dimming ECG
through intelligent power reduction at high t

c

temperatures

• 5-year system+ guarantee:
For every ECG that failed due to a material or production fault, a

replacement is available

• CELMA energy classification EEI = A1
• Maximum energy efficiency thanks to cut-off technology
• EoL shutdown acc. to EN/IEC 61347-2-3 Section 17

For use in emergency lighting systems acc. to EN 50172 / DIN VDE
0108-100

• Test mark: ENEC, VDE, EMC

EN 60929, EN 61347-2-3, EN 55015, EN 61000-3-2, EN 61547,
EN 61000-3-3

• Ordering designation for each type of lamp: QTi-T/E…DIM

QUICKTRONIC

®

INTELLIGENT DIM (1…10 V) for T5/Ø 16 mm

fluorescent lamps
Ordering designation for each type of lamp: QTi … DIM
• Intelligent ECG with 1…10 V interface acc. to IEC 60929

Operation of T5 fluorescent lamps of the same length in a luminaire
for the flexible adaptation of the light level

• Unrestrictedly dimmable from 1 % to 100 %

Max. dimming speed for dynamic RGB color light applications of
5 ms, from 1 % to 100 % through optimized regulation of the fila-
ment preheating

Warm start of the lamp inside 0.5 seconds without switch-on
flash

Manual dimming operation (TouchDIM) without any control gear
with standard installation buttons, incl. memory function (double-
click) and soft start

Service life: 50,000 h at maximum thermal load (t

c

= 75 °C, max.

10 % failure)

• 5-year system+ guarantee
For every ECG that failed due to a material or production fault,

a replacement is available

• CELMA energy classification EEI = A1
• Maximum energy efficiency thanks to cut-off technology