3.8

Temperature response of dimmable ECGs from OSRAM

Permissible standard values for minimum ambient light tempera-
tures:

Lamp type

Min. temperature
at 1 % (3 % CFL)
dimmer setting

Min. dimmer setting of
-20 °C to +10 °C

T8/26 mm lamp***

-20 °C*

1 %*

T5/16 mm lamp*
HE 14…35
HO 49
HO 24…80

+10 °C

60 %****
50 %
30 %

DULUX L*

+10 °C

30 %

DULUX D/E, T/E, FC

+10 °C**

50 %

Table 7

* Only with QTi…DIM ** 3…100 % *** L18 W, L36 W, L58 W, not
L70 W ****; The critical point from which the maintaining voltage
increases excessively for cold HO lamps lies just below the 30 % dim-
mer setting. For HE lamps, this point is reached at the same pow-
er density. Because of the 100 % power being approx. only half as
high, the dimmer setting is 60 % here. The HO49 lies between HE
14…35 W and HO 24…80 W/Dimming of the amalgam lamps T5 HO
CONSTANT (24 W, 39 W, 54 W, 80 W), CFL (DL CONSTANT 40 W,
55 W, 80 W and T/E IN PLUS 26 W, 32 W, 42 W, 57 W) is possible.

The temperature range of the luminaires can be expanded down-
wards by raising the lowest dimmer setting until the light has reached
a higher inner temperature, otherwise flickering or/and starting prob-
lems of the lamp can be expected. From the end of 2008 units do this
automatically.

3.8.1 Intelligent thermal management in hot luminaires

Intelligent thermal management enables operation in a wide ambient
temperature range through power reduction.

From the generation at the end of 2008, the QTi (DALI)…DIM ECG
from OSRAM include the feature of intelligent temperature regulation.

Features

Notable increase in the light yield (lm/W) of hot luminaires

Virtually no loss of luminous flux (lm) compared with uncontrolled
operation

No reduction in the service life of the ECG within the control range

Simplifies the safety approval of hot luminaires

Relieves luminaire components