Why are the light losses so small due to the temperature limitation?

Assuming a luminaire whose inside temperature (= lamp ambient
temperature)
is to be lowered from 65 °C to 55 °C. A reduction of
the system power by 20 % is required for this. The diagram shows the

Φ

(T) curves of T5 lamps for 100 % and 80 % system power.

During the transition from the 100 % curve to the 80 % curve and the
lowering of the lamp ambient temperature by 10 °C, the luminous
flux remains roughly the same
.

Figure 39: Temperature regulation and relative luminous flux

QTi (DALI)…DIM never stop thinking: Instructions for the ther-
mal coupling of lamp and ECG

Temperature limitation is control engineering in the classical sense
and requires, therefore, a closed control loop: The lamps must be
able to heat the ECG. This is ensured when the ECG and lamps are
housed in the same luminaire space, separated by a reflector if neces-
sary.

If the ECG is mounted outside the luminaire, it cannot exploit the ben-
efits of the thermal managment.

(T) curves of T5 lamps

0

20

40

60

80

100

120

0

10

20

30

40

50

60

70

80

Lamp ambient temperature [°C]

Relative luminous flux [%]

10 0 % system power


80 % system power

temperature