OSRAM OUTKIT 30S User Manual
OSRAM Lighting
Instruction and Safety advice for OUTKIT version 30 x 30
The housing is developed for electronic control gear (ECG) of OSRAM in a cross section of 30 x 30 mm in order
to reliably protect the ECG of humidity in IP67. OUTKIT
30 short is intended to protect 1lamp ECG in the
dimension of 360 x 30 x 30 mm and OUTKIT
30 long to protect 2lamp ECG in the dimensions of 423 x 30 x 30
mm . OUTKIT consists of the square pipe (1) , two pre-assembled screw caps out of single parts numbers 2, 3, 5
and 7 and bulk enclosed seal inserts for the use of single wires and 2 pcs. of caps (6).
To ensure reliable operation in IP 67 it is necessary that you follow the construction and safety information as
below:
Assembly instructions:
•
To mount the cable screw you need tools with a wrench size 22.
•
Within OUTKIT the ECG can be mounted with single wires or / and special ÖLFLEX 400P or 540P of
company U.I.Lapp GmbH
www.lappgroup.com
Please see below the tested and approved types of cables and single wires:
OUTKIT 30 short
Input side
Lamp side
wires
ÖLFLEX CLASSIC 400 P 2 x 0.75 or 540 P 2x 0.75
for PC II and ÖLFLEX CLASSIC 400 P 3 G 0.75 or
540 P 3G 0.75 for PC I
ÖLFLEX CLASSIC
400 P 4 x 0.75
single wires
H 05 V , max. diameter of 3 mm incl. a seal insert 2x3
or 3x3
H05 V , max. diameter of 3 mm incl. seal
insert 4x3
OUTKIT 30 long
Input side
Lamp side
wires
ÖLFLEX CLASSIC 400 P 2 x 0.75 or 540 P 2x 0.75
for PC II and ÖLFLEX CLASSIC 400 P 3 G 0.75 or
540 P 3G 0.75 for PC I
ÖLFLEX CLASSIC
400 P 7 x 0.75
single wires
H 05 V, max. diameter of 3 mm incl. a seal insert 2x3
or 3x3
H 05 V, max. diameter of 2.7 mm incl. a seal
insert 7x2.7
•
For the use of dimmable ECG you must use 2 additional wires at the Input Side.
ÖLFLEX CLASSIC 400 P 4x0.75 for PC I and 400 P 5 G 0.75 or 540 P 5 G 0.75 for PC II.
•
The cover caps (6) are put from outside into the two vents at the end of the ECG and secure the positioning
of the ECG within the square pipe
•
Press the cover caps to the joint of the square pipe and secure it with the tools of the wrench size 22:
Safety instruction:
1. No guarantee for the type of protection of the system if you use different cable manufacturer.
2. If you use OUTKIT as a semiluminaire for lamps and for different light sources as well as for the use of different
ECG brands we do not take any responsibility.