beautypg.com

B&B Electronics WLNN-EK-DP551 - User Manual User Manual

Page 33

background image

B&B Electronics

Airborne Enterprise WLNN EVB Users Guide

33

FIGURE 18 - SW2 RESET CIRCUIT



5.32 SW3

This push button switch allows the user to reset the Airborne Device Server
module settings back to OEM default. The button cannot reset settings by itself; it
requires either a power cycle or restart.

To reset the module configuration back to OEM defaults SW 3 must be pushed
and held while the restart or power cycle is initiated. It is required that SW 3 be
held for approximately 3 seconds after the restart or power cycle has been
initiated, it can then be released. The module will then continue the boot cycle
and the OEM parameter values will be reinstalled.

FIGURE 19 - OEM RESET CIRCUIT

Doing an OEM reset will reset all parameters back to OEM default values; this may

place the module in a state that will not allow the user to communicate with it.

IMPORTANT: Confirm that the OEM settings installed on the module will allow the
user to communicate with the module after the reset has been completed.




5.33 SW4

This is an additional SPDT switch that may be used in conjunction with the test
points (TP7, 8, 9, 10) to demonstrate functionality provided by the Airborne
Device Server module.

FIGURE 20 - SW4 CONFIGURATION