Rainbow Electronics DS2141A User Manual
Page 13
DS2141A
021997 13/35
SR2: STATUS REGISTER 2 (21h)
(MSB)
(LSB)
RMF
TMF
SEC
RFDL
TFDL
RMTCH
RAF
LORC
SYMBOL
POSITION
NAME AND DESCRIPTION
RMF
SR2.7
Receive Multiframe. Set on receive multiframe boundaries.
TMF
SR2.6
Transmit Multiframe. Set on transmit multiframe boundaries.
SEC
SR2.5
One Second Timer. Set on increments of one second based on RCLK; will
be set in increments of 999 ms, 999 ms, and 1002 ms every three seconds.
RFDL
SR2.4
Receive FDL Buffer Full. Set when the receive FDL buffer (RFDL) fills to
capacity (8–bits).
TFDL
SR2.3
Transmit FDL Buffer Empty. Set when the transmit FDL buffer (TFDL)
empties.
RMTCH
SR2.2
Receive FDL Match Occurrence. Set when the RFDL matches either
RFDLM1 or RFDLM2.
RAF
SR2.1
Receive FDL Abort. Set when eight consecutive 1’s are received in the
FDL.
LORC
SR2.0
Loss of Receive Clock. Set when the RCLK pin has not transitioned for at
least 2
µ
s (3
µ
s +1
µ
s).
IMR1: INTERRUPT MASK REGISTER 1 (7Fh)
(MSB)
(LSB)
LUP
LDN
LOTC
SLIP
RBL
RYEL
RCL
RLOS
SYMBOL
POSITION
NAME AND DESCRIPTION
LUP
IMR1.7
Loop Up Code Detected.
0=interrupt masked.
1=interrupt enabled.
LDN
IMR1.6
Loop Down Code Detected.
0=interrupt masked.
1=interrupt enabled.
LOTC
IMR1.5
Loss of Transmit Clock.
0=interrupt masked.
1=interrupt enabled.
SLIP
IMR1.4
Elastic Store Slip Occurrence.
0=interrupt masked.
1=interrupt enabled.
RBL
IMR1.3
Receive Blue Alarm.
0=interrupt masked.
1=interrupt enabled.
RYEL
IMR1.2
Receive Yellow Alarm.
0=interrupt masked.
1=interrupt enabled.