beautypg.com

Changing the set value, Figure 12, Front view of the temperature regulator – M&C TechGroup CSS-V2 Operator's manual User Manual

Page 25

background image

4-1.2-ME

Gas sampling and gas conditioning technology

25

16

OPERATING OF THE INTEGRATED ELECTRONIC TEMPERATURE REGULATOR

During normal operation, the display of the temperature regulator shows the actual cooling
temperature.

Figure 12

Front view of the temperature regulator


16.1

CHANGING THE SET VALUE

For changing the set value, press the P-button < 2s. The set value, adjusted at the factory to 5°C, is
shown. With both arrow keys, the set value can be set upwards or downwards. However, this value
should not be adjusted below +2°C, otherwise freezing up of the heat exchanger is possible. If the
value is set above ambient temperature, the cooler will not work.