A.1.3 DSL LED

The DSL LED on the front panel does not light up.

Chart A-3 Troubleshooting DSL LED

STEPS CORRECTIVE

ACTION

1

Check the telephone wire and connections between the Prestige DSL port and the wall jack.

2

Make sure that the telephone company has checked your phone line and set it up for DSL service.

3

Reset your ADSL line to reinitialize your link to the DSLAM. For details, refer to the Maintenance
chapter (web configurator) or the System Information and Diagnosis chapter (SMT).

4

If these steps fail to correct the problem, contact your local distributor for assistance.

A.2 Console Port

I cannot access the Prestige via the console port.

Chart A-4 Troubleshooting Console Port

STEPS CORRECTIVE

ACTION

1

Make sure the Prestige is connected to your computer's serial port.

2

Make sure the communications
program is configured correctly. The
communications software should be
configured as follows:

VT100 terminal emulation.

9600 bps is the default speed on leaving the factory. Try
other speeds in case the speed has been changed.

No parity, 8 data bits, 1 stop bit, data flow set to none.

3

Make sure you entered the correct password. The default password is “1234”.

If you have forgot your username or password, refer to Section A.5.

A.3 Telnet

I cannot telnet into the Prestige.

Chart A-5 Troubleshooting Telnet

STEPS CORRECTIVE

ACTION

1

Check the LAN port and the other Ethernet connections.