beautypg.com

Snmp traps, 4 snmp traps – ZyXEL Communications 650 Series User Manual

Page 368

background image

Prestige 650 Series User’s Guide

33-4

SNMP

Configuration

33.4 SNMP Traps

The Prestige will send traps to the SNMP manager when any one of the following events occurs:

Table 33-2 SNMP Traps

TRAP #

TRAP NAME

DESCRIPTION

1 coldStart

(defined in RFC-1215)

A trap is sent after booting (power on).

2 warmStart

(defined in RFC-1215)

A trap is sent after booting (software reboot).

3 linkDown

(defined in RFC-1215)

A trap is sent when the port is down.

4 linkUp

(defined in RFC-1215)

A trap is sent when the port is up.

5 authenticationFailure

(defined in

RFC-1215)

A trap is sent to the manager when receiving any SNMP
get or set requirements with wrong community (password).

6

whyReboot (defined in ZYXEL-
MIB)

A trap is sent with the reason of restart before rebooting
when the system is going to restart (warm start).

6a

For intentional reboot :

A trap is sent with the message "System reboot by user!" if
reboot is done intentionally, (for example, download new
files, CI command "sys reboot", etc.).

The following table maps the physical port and encapsulation to the interface type.

Table 33-3 Ports and Interface Types

PHYSICAL PORT/ENCAP

INTERFACE TYPE

LAN port(s)

enet0

Wireless port

enet1

PPPoE encap

pppoe

1483 encap

mpoa

Ethernet encap

enet-encap

PPPoA

ppp