Spartan-3A DSP FPGA Family: DC and Switching Characteristics
DS610 (v3.0) October 4, 2010
Product Specification
11
General Recommended Operating Conditions
Table 7: General Recommended Operating Conditions
Symbol
Description
Min
Nominal
Max
Units
T
J
Junction temperature
Commercial
0
–
85
°C
Industrial
–40
–
100
°C
V
CCINT
Internal supply voltage
1.14
1.20
1.26
V
V
CCO
Output driver supply voltage
1.10
–
3.60
V
V
CCAUX
Auxiliary supply voltage
V
CCAUX
= 2.5
2.25
2.50
2.75
V
V
CCAUX
= 3.3
3.00
3.30
3.60
V
V
Input voltage
PCI™ IOSTANDARD
–0.5
–
V
CCO
+0.5
V
All other
IOSTANDARDs
IP or IO_#
–0.5
–
4.10
V
IO_Lxxy_#
–0.5
–
4.10
V
T
IN
Input signal transition time
(5)
–
–
500
ns
Notes:
1.
This V
CCO
range spans the lowest and highest operating voltages for all supported I/O standards.
lists the recommended V
CCO
range specific to each of the single-ended I/O standards, and
lists that specific to the differential standards.
2.
Define V
CCAUX
selection using CONFIG VCCAUX constraint.
3.
4.
For single-ended signals that are placed on a differential-capable I/O, V
IN
of –0.2V to –0.5V is supported but can cause increased leakage
between the two pins. See Parasitic Leakage in
, Spartan-3 Generation FPGA User Guide.
5.
Measured between 10% and 90% V
CCO
recommendations.