Calibration list – Xerox CX240 User Manual
Page 133
Using Calibration Tables
123
The following options are available:
•
Click
Calibrate
to run the Color Calibration Wizard. This wizard
guides you in the use of the X-Rite DTP34 QuickCal densitometer to
create calibration tables, see Creating a Calibration Table on page 116.
•
Select a calibration table from the
Calibration List
and click
Delete
to
delete the calibration table.
•
Click
Close
to close the Calibration window.
Calibration List
The Spire CX250 color server uses calibration tables to compensate for the
difference between the printer’s performance and the required values.
The following calibration look up tables are provided:
•
SpireNormal:
Applies the factory default calibration table. Since this is
a default lookup table, it cannot be overwritten.
•
SpireSaturated:
Applies the factory default saturated calibration table.
This look up table applies a darker calibration table in comparison to
the
SpireNormal
look up table. Since this look up table is a default table
it cannot be overwritten.
•
Normal:
Initially the
Normal
look up table is identical to the
SpireNormal
look up table. This resemblance changes as soon as you
calibrate your Spire CX250 color server, and at the end of the
calibration process choose to save your calibration table
as default. As
a result, your calibration table is saved as the
Normal
look up table.
•
Saturated:
Initially the
Saturated
look up table is identical to the
SpireSaturated
look up table. This resemblance changes as soon as you
calibrate your Spire CX250 color server, and at the end of the
calibration process choose to save your calibration table
as default. As
a result, your calibration table is saved as the
Saturated
look up table.
•
Select
None
if you do not want to apply a calibration table to the job.