Defining the calibration device, Scanner calibration – Xerox CX240 User Manual
Page 119

Defining the Calibration Device
109
Defining the Calibration Device
If you have the basic or Control Station configuration, you can only
calibrate using the scanner calibration method.
If you have the Pro configuration, the default calibration mode is scanner
calibration. If you want to calibrate using the X-Rite DTP34 QuickCal
densitometer, set the calibration method to external device.
¾
In the Settings window, set the
Calibration Device
option to
use
external calibration device
.
Scanner Calibration
This section describes the scanner calibration process.
1.
In the Spire CX250 color server application, from the
Tools
menu,
select
Calibration
.
2.
In the Calibration window, click
Calibrate
.
Note: This option is available only if you have the Pro configuration. For more
information, see Calibration Device on page 155.
Note:
It is recommended that:
1.
After you perform the first calibration, you print the IQ Test.pdf file from
the D:\Shared\Sample Files folder. Each time you calibrate, use this file as
a visual reference to verify that the printer has returned to its start point.
2.
You calibrate both the printer and scanner at the same time. If you only
place the print chart on the platen, the printer is calibrated. If you only place
the scanner chart on the platen, the scanner is calibrated.