Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual
Page 346

323
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
Appendix C
CX-Programmer: Pulse Output Tab Page
+323
00 to 03 High-speed
counter 2 (Counter
2)
Input method
Same as for high-speed counter 1 except that fre-
quency measurement (Counter data to monitor,
bit 00 to 03 of +324: 02 hex) cannot be set for
high-speed counter 2.
At power ON
04 to 07
Reset method
08 to 11
Counting speed
12 to 15
Counter operating
mode (Counter opera-
tion)
+324
00 to 03
Counter data to moni-
tor (Counter data dis-
play)
04 to 15
Reserved
+325
00 to 15
Sampling time (for
mode 1 only)
+326 to 327 00 to 15 High-speed
counter 1 (Counter
1)
Circular maximum
count
Sets the maximum circular counter value.
Range: 0000 0001 to FFFF FFFF hex
Absolute encoder res-
olution
0000 0001 to 0000 FFFF hex
Note Set this value in pulses/rotation according
to the encoder dividing ratio set for the Servo
Driver and the input method multiplier set for the
Module.
Example: If the Servo Driver setting is 1,000 and
the Module setting is x4, set FA0 (4,000).
+328 to 329 00 to 15 High-speed
counter 2 (Counter
2)
Circular maximum
count
Same as for high-speed counter 1.
Absolute encoder res-
olution
+330 to 331 00 to 15 High-speed
counter 1 (Counter
1)
Absolute offset
8000 0000 to 7FFF FFFF hex
+332 to 333 00 to 15 High-speed
counter 2 (Counter
2)
Absolute offset
8000 0000 to 7FFF FFFF hex
Address
Bits
Function
Remarks
When setting is
read
+340
00 to 07 Pulse output 1
Operation mode
(Refer to 7-6-6
Pulse Output
Function Details.)
00 hex: Relative pulse output
01 hex: Absolute pulse output in linear mode
02 hex: Absolute pulse output in circular mode (See
note.)
03 hex: Electronic cam control in linear mode (See
note.)
04 hex: One-shot pulse output
05 hex: Time measurement using pulse counter
06 hex: Electronic cam control in circular mode (See
note.)
At power ON
08 to 15
Clock
00 hex: 20 MHz
Pulse output frequency: 400 Hz
to 1 MHz
01 hex: 10 MHz
Pulse output frequency: 200 Hz
to 200 kHz
02 hex: 5 MHz
Pulse output frequency: 100 Hz
to 100 kHz
03 hex: 2.5 MHz
Pulse output frequency: 40 Hz
to 50 kHz
04 hex: 1.25 MHz
Pulse output frequency: 20 Hz
to 20 kHz
+341
00 to 07 Pulse output 2
Operation mode
Same as for pulse output 1.
08 to 15
Clock
+342 to 343 00 to 15 Pulse output 1
Circular maximum
count
Sets the maximum circular counter value when the
pulse output mode is set to absolute pulse output in
circular mode or electronic cam control in circular
mode.
Range: 0000 0001 to FFFF FFFF hex (See note.)
+344 to
+345
00 to 15 Pulse output 2
Circular maximum
count
Same as for pulse output 1.
Address
Bits
Function
Remarks
When setting is
read