Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual
Page 221

198
Pulse Outputs
Section 7-6
Note
The pulse output will stop. After the axis stops, it must be restarted.
Cases (6), (8), (9), and (10)
• Starting instruction: ACC(888) (continuous or independent), acceleration, relative
• Starting instruction: ACC(888) (continuous or independent), acceleration, absolute
linear
• Starting instruction: ACC(888) (continuous or independent), acceleration, absolute
circular
Cases (7), (11), (12), (13)
• Starting instruction: ACC(888) (continuous or independent), deceleration, relative
• Starting instruction: ACC(888) (continuous or independent), deceleration, absolute
linear
Output status
Direction and starting conditions
CW
CCW
Target
position >
Present
position
Target
position <
Present
position
Target
position >
Present
position
Target
position <
Present
position
Relative
CW output
Yes
No
No
No
CCW output
No
No
Yes
No
Output status
Direction and starting conditions
CW
CCW
Target
position >
Present
position
Target
position <
Present
position
Target
position >
Present
position
Target
position <
Present
position
Absolute lin-
ear
CW output
Yes
No
No
No
CCW output
No
No
Yes
No
Output status
Direction and starting conditions
CW
CCW
Target
position >
Present
position
Target
position <
Present
position
Target
position >
Present
position
Target
position <
Present
position
Absolute cir-
cular
CW output
Yes
No
No
No
CCW output
No
No
Yes
No
Output status
Direction and starting conditions
CW
CCW
Target
position >
Present
position
Target
position <
Present
position
Target
position >
Present
position
Target
position <
Present
position
Relative
CW output
No
Yes
No
No
CCW output
No
No
No
Yes
Output status
Direction and starting conditions
CW
CCW
Target
position >
Present
position
Target
position <
Present
position
Target
position >
Present
position
Target
position <
Present
position
Absolute lin-
ear
CW output
No
Yes
No
No
CCW output
No
No
No
Yes