Settings Common to All Modes (System Mode)

Settings Common to All Modes (System Mode)

EQ

fig.05-02_50

4 Band EQ (4-Band Equalizer Switch)

Switch the 4-Band equalizer on/off.

Value:

OFF, ON

LOW Freq (Low Frequency)

Selects the frequency of the low range.

Value:

50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000,

1250, 1600, 2000, 2500, 3150, 4000 Hz

LOW Gain

Adjusts the gain of the low frequency. Positive (+) settings will
emphasize the low-frequency range.

Value:

-15– +15 dB

MID 1 Q

Adjusts the width of the middle range 1. Set a higher value for Q to
narrow the range to be affected.

Value:

0.5, 0.7, 1.0, 2.0, 4.0, 8.0

MID 1 Freq (Mid 1 Frequency)

Selects the frequency of the middle range 1.

Value:

50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000,

1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000, 12500,
16000, 20000 Hz

MID 1 Gain

Adjusts the gain of the middle range 1. Positive (+) settings will
emphasize the middle range 1.

Value:

-15–+15 dB

MID 2 Q

Adjusts the width of the middle range 2. Set a higher value for Q to
narrow the range to be affected.

Value:

0.5, 0.7, 1.0, 2.0, 4.0, 8.0

MID 2 Freq (Mid 2 Frequency)

Selects the frequency of the middle range 2.

Value:

50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000,

1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000, 12500,
16000, 20000 Hz

MID 2 Gain

Adjusts the gain of the middle range 1. Positive (+) settings will
emphasize the middle range 2.

Value:

-15–+15 dB

High Freq (High Frequency)

Selects the frequency of the high range.

Value:

2000, 4000, 5000, 6300, 8000, 10000, 12500, 16000, 20000 Hz

HIGH Gain

Adjusts the gain of the high frequency. Positive (+) settings will
emphasize the high-frequency range.

Value:

-15– +15 dB

TOTAL Gain

Adjusts the total gain.

Value:

-15– +15 dB

MIDI/USB

fig.05-03_50

Device ID (Device ID Number)

When you want to transmit or receive System Exclusive messages,
set this parameter to match the Device ID number of the other MIDI
device.

Value:

17–32

Clock Source

The LFO cycle or multi-effects changes can be synchronized to a
clock (tempo). When this is used by the patch, this Clock Source
setting determines the clock which will be used.

Value

INTERNAL:

The Patch Tempo will be used.

EXTERNAL:

Synchronize to the clock of an external sequencer.

Rx PC (Receive Program Change Switch)

Specifies whether Program Change messages will be received (ON)
or not (OFF).

Value:

OFF, ON

Rx Bank (Receive Bank Select Switch)

Specifies whether Bank Select messages will be received (ON) or not
(OFF).

Value:

OFF, ON