beautypg.com

Bass multi, P. 134), 134 effects list – Roland V-Synth User Manual

Page 134

background image

134

Effects List

35: Bass Multi

Bass Multi provides Comp/Limiter, Overdrive or Distortion, 3-band
equalizer, and Chorus or Flanger effects connected in series. This
algorithm is a multi-effects for bass.

fig.MFX-35

Mod Mode

CHORUS,
FLANGER

Selects whether to use chorus or
flanger.

Mod Rate

0.05–10.0 Hz,
note

Adjusts the speed of modulation
for the chorus or flanger.

Mod Depth

0–127

Adjusts the depth of modulation
for the chorus or flanger.

Mod Phase

0–180 deg

Sets how the chorus or flanger
sound is spread.

Mod Pre Delay

0–50.0 ms

Adjusts the delay time from the
direct sound until the chorus or
flanger sound is heard.

Mod Feedback

-98– +98 %

Adjusts the proportion of the ef-
fect sound that is fed back into
the effect. Negative (-) settings
will invert the phase.

Mod XoverLPF

500–15000 Hz,
THRU

Adjusts the cutoff frequency of
the low pass filter. (THRU: no
filter is used)

Mod XoverHPF THRU, 50–800

Hz

Adjusts the cutoff frequency of
the high pass filter. (THRU: no
filter is used)

Mod Level

0–127

Volume of the chorus or flanger
sound.

Delay Time

0–1300 ms, note Adjusts the delay time from the

direct sound until the delay
sound is heard.

Delay Feedback -98– +98 %

Adjusts the proportion of the de-
lay sound that is fed back into
the effect. Negative (-) settings
will invert the phase.

Hi Damp Freq

500–15000 Hz,
THRU

Adjusts the frequency above
which sound fed back to the ef-
fect will be cut.
High Damp, by attenuating the
higher frequencies first, makes
the delay sound more natural.

Delay Level

0–127

Volume of the delay sound.

Parameter

Value

Description

Comp Sw

OFF, ON

Turns the comp/limiter on/off.

Comp Thresh-
old #1

-60–0 dB

Sets the volume level at which
the compression begins.

Comp Attack

0–127

Sets the time after the sound vol-
ume is crossed the compressor
threshold until compression be-
gins.

Comp Release

0–127

Specifies the time from when the
volume drops below the com-
pressor threshold until com-
pression is no longer applied.

Comp Ratio

1.5:1, 2:1, 4:1,
100:1

Sets the “source sound:output
sound” compression ratio.

Comp Gain

-60– +12 dB

Adjusts the output gain.

Parameter

Value

Description

3-Band

EQ

Chorus/

Flanger

Overdrive/

Distortion

L

R

Comp/
Limiter

Distortion Sw

OFF, ON

Selects whether to use overdrive
or distortion.

Distortion
Mode

OD, DS

Selects whether to use overdrive
(OD) or distortion (DS).

Drive

0–127

Degree of distortion

Amp Sim Sw

OFF, ON

Turns the amp simulator on/off.

Amp Type

SMALL,
BUILT-IN, 2-
STACK, 3-
STACK

Type of guitar amp
SMALL: small amp
BUILT-IN: single-unit type amp
2-STACK: large double stack
amp
3-STACK: large triple stack amp

Distortion Level 0–127

Volume of the overdrive or dis-
tortion sound.

EQ Low Freq

50–4000 Hz

Frequency of the low range

EQ Low Gain

-15– +15 dB

Gain of the low range

EQ Mid Freq

50–20000 Hz

Frequency of the middle range

EQ Mid Q

0.5, 0.7, 1.0, 2.0,
4.0, 8.0

Gain of the middle range
Set a higher value for Q to nar-
row the range to be affected.

EQ Mid Gain

-15– +15 dB

Gain of the middle range

EQ Hi Freq

2000–20000 Hz

Frequency of the high range

EQ Hi Gain

-15– +15 dB

Gain of the high range

Mod Mode

CHORUS,
FLANGER

Selects whether to use chorus or
flanger.

Mod Rate

0.05–10.0 Hz,
note

Adjusts the speed of modulation
for the chorus or flanger.

Mod Depth

0–127

Adjusts the depth of modulation
for the chorus or flanger.

Mod Phase

0–180 deg

Sets how the chorus or flanger
sound is spread.

Mod Pre Delay

0–50.0 ms

Adjusts the delay time from the
direct sound until the chorus or
flanger sound is heard.

Mod Feedback

-98– +98 %

Adjusts the proportion of the ef-
fect sound that is fed back into
the effect. Negative (-) settings
will invert the phase.

Mod XoverLPF

500–15000 Hz,
THRU

Adjusts the cutoff frequency of
the low pass filter. (THRU: no
filter is used)

Mod XoverHPF THRU, 50–800

Hz

Adjusts the cutoff frequency of
the high pass filter. (THRU: no
filter is used)

Mod Level

0–127

Volume of the chorus or flanger
sound.

Parameter

Value

Description