beautypg.com

Loop region settings, Loop point location (loop start, loop end) (p. 68), 68 creating and editing samples (sample mode) – Roland V-Synth User Manual

Page 68

background image

68

Creating and Editing Samples (Sample Mode)

If you normalize at a low setting and then normalize at a high
setting, the audio quality will deteriorate. This means that if you
intend to normalize several times, you should start from the
higher value and work downward.

Reverse

The sample will be reversed between Edit Start and Edit End. If you
want the sample to play backwards, execute Reverse to reverse the
sample from the beginning.

Region

The region of the sample between Edit Start and Edit End can be
stored in internal memory as a separate sample. The original sample
will remain unchanged.

Perform the following procedure.

1.

Select the region that you want to extract as a separate

sample, and execute Region.

2.

In the SAMPLE Edit Region window, select the sample

number to which you want to paste the extracted region of

the sample, and touch .

3.

Assign a name to the new sample, and touch .

If in step 2 you select a sample number that already has a
sample, the sample data between Edit Start and Edit End will be
added to the end of the selected sample.

Loop Region Settings

When the loop switch (p. 65) is ON, you can specify the region that
will be played back as a loop. The region of the sample between
Loop Start and Loop End will be played back repeatedly.

In the SAMPLE Loop FWD screen that appears when you touch
, specify the loop region for forward playback. In the
SAMPLE Loop BWD screen that appears when you touch BWD>, specify the loop region for backward playback.

fig.04-13_50

Immediately after sampling or loading a sample, Loop Start will be
set to the beginning of the sample and Loop End to the end of the
sample.

If you set Loop Start and Loop End to locations within the sample,
the sample will play back from the beginning, and then the region
between Loop Start and Loop End will play back repeatedly.

fig.04-14.e

The data in the V-Synth is handled as 44.1 kHz data, which
means there are 44,100 data samples per second. The shortest
possible loop that can be set is 16 data samples.

Loop range settings are ignored when the Playback Mode (p. 43)
is set to “STEP” or “EVENT.”

Loop

Start

Loop

End

Wave

Start

Wave

End