User interface fundamentals
3
Click OK.
--End--
Setting properties after access
Procedure Steps
Step
Action
1
To set Device manager properties after you access a device,
from the Device Manager menu bar choose Device > Properties
> Devices.
2
Select the IP address of a device from the Properties Device
List.
3
Click Edit.
4
Configure the properties in the Properties window.
5
Click OK.
--End--
Variable definitions
Area
Item
Description
Status Interval
Interval at which statistics and status information is gathered.
For a full stack, set this interval to between 120 and 300
seconds.
Hotswap Detect
every
The frequency at which Device Manager polls for hot swap
module information. This value relates to the Status Interval
value. For example, if the status Interval is set to 120, and the
value for Hotswap Detect every is 2, Device Manager polls
the hot swap modules every 240 seconds. For less hot swap
polling, set the value to poll every 2 or 3 intervals.
Polling
Enable
Enables (true) or disables (false) periodic polling of the device
for updated status. If polling is disabled, the chassis status is
updated only after you choose Device > Refresh Status.