beautypg.com

NEC Express5800 Series EXP320B User Manual

Page 303

background image

Troubleshooting 7-31

Event Log

HAS Daemon-related logs are recorded in the system event log.

o When you manage servers using NEC ESMPRO Manager, the following message

may be recorded in the system event log. This message does not indicate an event
that impacts operations. However, if it is recorded frequently, there may be
problem in OS or the software environment. Contact your sales agent.

Source:

HAS Daemon

Type:

Warning

Event ID: 800000cc – 800000d2

o The following message may be recorded in the system event log for operation or

replacement maintenance of each network adapter, SCSI disk or fibre channel.
This message does not indicate an event that impacts operations. However, if it is
recorded frequently or even when maintenance procedures are followed, there
may be problem in OS or the software environment. Contact your sales agent.

Source:

HAS Daemon

Type:

Warning

Event ID: 800000cc – 800000d2

hasftctl-related logs are recorded in the system event log.

o The following message may be recorded in the system event log. This log does not

indicate an event that impacts operations. This message informs that the CPU
modules are no longer in the duplex mode. However, dual configuration is to be
set to the CPU modules again, so this warning does not indicate any impact on the
system operation.

Source:

hasftctl

Type:

Warning

Event ID: 800704B2
Description: The driver failed the fast re-sync function of the CPU module.

Source:

hasftctl

Type:

Warning

Event ID: 80070DAC
Description: The error occurred on the CPU module.

Source:

hasftctl

Type:

Warning

Event ID: 80070fa0
Description: The error occurred on the CPU module.

Source:

hasftctl

Type:

Warning

Event ID: 40071209
Description: CPU is not doubled.