NEC Express5800 Series EXP320B User Manual
Page 278
7-6 Troubleshooting
On-screen error message
Cause
Action
0B83 BMC IBF or OBF
check
failed
RMC device is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8A BMC SEL area full
There is no space to write
system event logs.
Clear system event logs after
saving them.
0B8B BMC progress check
timeout
BMC check is suspended.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8C BMC command
access failed
BMC command access failed.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8D Could not redirect the
console - BMC Busy
Console cannot be redirected
(BMC is busy).
There is a possibility that the
BMC was busy and could not
respond. Restart the server
again.
0B8E Could not redirect the
console - BMC Error
BMC is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8F Could not redirect the
console – BMC
parameter Error -
Configuration is faulty.
Configure the console redirection
by using BIOS setup.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC device is faulty.
0B92 Internal Use Area of
BMC FRU corrupted
Data within SROM is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B93 BMC SDR Repository
empty
SDR data is faulty.
If updating SDR does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
0B94 IPMB signal lines do
not respond
SMC is faulty.
Replace the CPU/IO module or a
center plane after determining
where IPMB error has occurred
based on OS information.
0B95 BMC FRU device
failure
NVRAM within BMC is faulty.
0B96 BMC SDR Repository
failure
SDR repository within BMC is
faulty.
0B97 BMC SEL device
failure
SEL repository within BMC is
faulty.
0B98 BMC RAM test error
BMC RAM is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B99 BMC Fatal hardware
error
BMC FPGA is faulty.
If updating FPGA does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
0B9A BMC not responding
BMC device is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B9B Private I2C bus not
responding
I2C bus is faulty.
Replace the part related to failed
I2C bus.