Troubleshooting 7-11

On-screen error message

Cause

Action

9058 - 905F

This CPU/IO module detected
the mismatch of CPUID
between the CPU/IO
modules.

CPU configuration may be
different between the CPU/IO
modules.
Replace the CPU.
If this does not help, replace the
CPU/IO module.

9062 - 9063

CPU/IO module or ft Remote
Management Card (option) is
faulty.

If turning AC power off and on
does not help, replace the
CPU/IO module or ft Remote
Management Card (option).

9065

One or both the CPU/IO
modules have a problem.

There are some error messages
in addition to this error code.
Check the other error message.

9071 - 9072

Water-cooling kit has leaked
out.

Replace the water-cooling kit.
If this does not help, replace the
CPU/IO module.

9080 - 908F
9080 - 9085
9087 - 908F

This CPU/IO module failed to
get the information from
another CPU/IO module.

When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.

9086

The CPU/IO modules were
unsuccessful to share
information.

The GA driver may not support
the server. Confirm that the driver
is an appropriate one and restart
the server.

If this does not help, replace the
CPU/IO module or center plane.

9026

The chip set revisions are
mismatched.

The model of the CPU/IO
modules mounted to the CPU
modules is different. Replace the
CPU/IO modules with those of
the same model.