Troubleshooting 7-5

On-screen error message

Cause

Action

0251 System CMOS

checksum bad-Default
configuration used

System CMOS configuration
is changed.

x

Reconfigure the system CMOS
by using BIOS setup.

x

Clear system CMOS using
hardware jumper.

0252 Password checksum

bad -Password cleared

Password is cleared.

x

Reconfigure by using BIOS
setup.

x

Clear system CMOS using
hardware jumper.

0260 System Timer error

System Timer is faulty.

0270 Real time clock error

RTC is faulty.

0271 Check date and time

setting

Date and time are incorrectly
set.

Reconfigure by using BIOS setup.

02D0 System cache error -

Cache disabled

CPU cache is faulty.

02D1 System Memory

exceeds the CPU's
caching limit

CPU cache is faulty.

If replacing the CPU does not
help, replace the CPU/IO module.

0613 COM A configuration

change

COM A configuration is faulty.

0614 COM A config, error -

device disable

Device constructing COM A is
faulty.

If restarting does not help after
resetting the setting to default by
using BIOS setup, replace the
CPU/IO module.

0B28 Unsupported

Processor detected on
Processor 1

Unsupported CPU is mounted.

0B29 Unsupported

Processor detected on
Processor 2

Unsupported CPU is mounted.

Check the supported CPU and
replace it. If this does not help,
replace the CPU/IO module.

0B60 DIMM group #1 has

been disabled

Replace DIMM Group#1.

0B61 DIMM group #2 has

been disabled

Replace DIMM Group#2.

0B62 DIMM group #3 has

been disabled

DIMM is faulty.

Replace DIMM Group#3.

0B70 The error occurred

during temperature
sensor reading

I2C pass is faulty.
Sensor is faulty.

Replace the part that relevant
sensor is mounted.

0B71 System Temperature

out of the range

Temperature is abnormal.
Fan is abnormal.

Check if fan is faulty or clogging
has occurred. If there is no
problem, replace CPU/IO module.

0B74 The error occurred

during voltage sensor
reading

I2C pass is faulty.
Sensor is faulty.

Replace the part that relevant
sensor is mounted.

0B75 System voltage out of

the range

Voltage is abnormal.

If turning AC power off and on
does not help, replace the
CPU/IO module.

0B80 BMC Memory Test

Failed

RMC device is faulty.

0B81 BMC Firmware Code

Area CRC check failed

Replace the CPU/IO module or ft
Remote Management Card
(option).

0B82 BMC core Hardware

failure