NEC PD750008 User Manual
Page 276
256
µPD750008 USER'S MANUAL
In
Mne-
Number
Machine
Address-
struc-
monic
Operand
of
cycle
Operation
ing
Skip condition
tion
bytes
area
SEL
RBn
2
2
RBS <– n (n=0 - 3)
MBn
2
2
MBS <– n (n=0, 1, 15)
GETI
Note
taddr
1
3
• µPD750004
*10
When the TBR instruction is used
PC
11-0
<– (taddr)
3-0
+(taddr+1)
When the TCALL instruction is used
(SP–4)(SP–1)(SP–2) <– PC
11-0
(SP–3) <– MBE, RBE, 0, 0
PC
11-0
<– (taddr)
3-0
+(taddr+1)
SP <– SP–4
When an instruction other than
Depends on the
the TBR or TCALL instruction is
referenced
used
instruction
Execution of (taddr)(taddr+1)
instruction
• µPD750006, µPD750008
When the TBR instruction is used
PC
12-0
<– (taddr)
4-0
+(taddr+1)
When the TCALL instruction is used
(SP–4)(SP–1)(SP–2) <- PC
11-0
(SP–3) <– MBE, RBE, 0, PC
12
PC
12-0
<– (taddr)
4-0
+(taddr+1)
SP <– SP–4
When an instruction other than
Depends on the
the TBR or TCALL instruction is
referenced
used
instruction
Execution of (taddr)(taddr+1)
instruction
• µPD75P0016
When the TBR instruction is used
PC
13-0
<– (taddr)
5-0
+(taddr+1)
When the TCALL instruction is used
(SP–4)(SP–1)(SP–2) <- PC
11-0
(SP–3) <– MBE, RBE, PC
13
, PC
12
PC
13-0
<– (taddr)
5-0
+(taddr+1)
SP <– SP–4
When an instruction other than
Depends on the
the TBR or TCALL instruction is
referenced
used
instruction
Execution of (taddr)(taddr+1)
instruction
Note The TBR and TCALL instructions are assembler pseudo instructions to define tables used for GETI
instructions.
Special