Pca9665 – NXP Semiconductors PCA9665 User Manual
Page 44
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx
xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx
PCA9665_2
© NXP B
.V
. 2006. All r
ights reser
v
ed.
Pr
oduct data sheet
Re
v
. 02 — 7 December 2006
44 of 91
NXP Semiconductor
s
PCA9665
Fm+ parallel b
us to I
2
C-b
us contr
oller
E8h
Previously addressed
with General Call;
BC[6:0] data bytes
have been received;
ACK has been
returned for all the
bytes, except for the
last one where NACK
bit has been returned
Read data bytes
or
X
X
0
X
0
0
1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
Read data bytes
or
X
X
0
X
0
1
1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
Read data bytes
or
X
X
1
X
0
0
1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Read data bytes
X
X
1
X
0
1
1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
A0h
A STOP condition or
repeated START
condition has been
received while still
addressed as slave
receiver
No I2CDAT action
or
X
X
0
X
0
0
1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
No I2CDAT action
or
X
X
0
X
0
1
1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
No I2CDAT action
or
X
X
1
X
0
0
1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
No I2CDAT action X
X
1
X
0
1
1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Table 40.
Slave Receiver Buffered mode (MODE = 1)
…continued
Status
code
(I2CSTA)
Status of the
I
2
C-bus and the
PCA9665
Application software response
Next action taken by the PCA9665
To/from I2CDAT
To/from I2CCOUNT
To I2CCON
LB
BC[6:0]
STA STO SI
AA
MODE