Super High-Capacity (Model WA3010)

310

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual

8.3.2.3

Safety Data

8.3.2.4

Safety License

Temp./Humidity
Cycle

After standard charge, carry out 5 cycles of the fol-
lowing: 65°C and 90% humidity for 8 hrs.
25°C and 65% humidity for 4 hrs.
-20°C for 8 hrs. 25°C and 65% humidity for 4 hrs.
Following that, perform a fast discharge, standard
charge and then a fast discharge. Measure the time
taken for the second discharge.

100 minutes or more

Dry heat

After standard charge, keep the battery at 60°C for 8
hrs. Carry out a fast discharge, standard charge and
then a fast discharge. Measure the time taken for the
second discharge.

100 minutes or more

EMC/CE Testing

The battery will need to pass the requirements of the
EMC directive 89/336/EEC (and amendments) when
fitted into the product:
Emissions to EN55022 Class B (1998) Immunity to
EN55024 (1998)

Test to be performed
by manufacturer.

Electro-Static Dis-
charge Test

EN61000-4-8:
A. Contact Discharge: +/-8kV for each contact pad
by 10 times.
B. Air Discharge: +/-15kV for 10 times (the dis-
charge test point is for around battery casing.)

No damage

Description

Condition

Test Condition/Result

Short Circuit Test

After a standard charge, short
terminals and discharge for 1 hr.

Protection circuit board to operate.
No explosion, fire, smoke, or leakage.

Over Charging Test

After a standard charge, charge
continuously at 4.2V and 4A for
8 hrs.

Protection circuit board to operate.
No explosion, fire, smoke, or leakage.

Reverse Charging Test

After a standard discharge,
reverse-charge continuously at
4.2V and 4A for 8hrs.

Protection circuit board to operate.
No explosion, fire, smoke, or leakage.

Item

License

Standard

1

UL 1642

The lithium-ion cell has been listed and pass the UL1642 stan-
dard by UL Lab. File No. MH12383

Description

Condition

Standard