20 micro pdf-417, 21 codablock, 20 micro pdf-417 5.27.3.21 codablock – Psion Teklogix ISO 9001 User Manual
Page 202: Field size/char, Enabled, Code 128 emulation, Enable codablock a, Enable codablock f
Chapter 5: Settings
Decoded
184
WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual
Field Size/Char
Refer to page 136 for details.
5.27.3.20 Micro PDF-417
Enabled
Set this parameter to on to enable “Micro PDF-417”.
Code 128 Emulation
When this parameter is enabled, the scanner transmits data from certain Micro PDF-
417 symbols as if it was encoded in Code 128 symbols.
If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are
transmitted with one of the following prefixes:
]C1
if the first codeword is 903-907, 912, 914, 915
]C2
if the first codeword is 908 or 909
]C0
if the first codeword is 910 or 911
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted
with one of the following prefixes:
]L3
if the first codeword is 903-907, 912, 914, 915
]L4
if the first codeword is 908 or 909
]L5
if the first codeword is 910 or 911
Field Size/Char
Refer to page 136 for details.
5.27.3.21 Codablock
Enable Codablock A
Set this parameter to on to enable “Codablock type A”.
Enable Codablock F
Set this parameter to on to enable “Codablock type F”.
Field Size/Char