beautypg.com

2 standard discharge, Standard discharge, Battery pack electrical specifications – Psion Teklogix ISO 9001 User Manual

Page 323: Acceptance test specifications

background image

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 305

Chapter 8: Specifications

High-Capacity (Model WA3006)

Battery Pack Electrical Specifications

8.3.1.2

Standard Discharge

Note: Standard charge is defined as charging with constant voltage limit of 4.2V

and constant current limit of 0.9A; the termination charge occurs when
the current drops to 45mA.

Standard discharge is defined as discharging at a constant current of
350mA until the battery protection circuit switches the battery output off in
over-discharge mode.

Acceptance Test Specifications

Description

Specification

Minimum

Typical

Maximum

Over voltage detection voltage

4.325V

4.350V

4.375V

Charge enable

4.10V

4.15V

4.20V

Under voltage detection voltage 2.5V

2.6V

2.7V

Over current detection current

-

3.5A

-

Short-circuit detection current

5.0A

8.0A

11.0A

Short-circuit detection voltage

150mV

200mV

250mV

Over voltage delay time

0.8s

1s

1.2s

Under voltage delay time

90ms

100ms

110ms

Over current delay time

5ms

10ms

20ms

Short-circuit delay time

160µs

200µs

240µs

Recovery charge current

0.5mA

1mA

2mA

Description

Condition

Standard

Open circuit voltage

After standard charge, measure within 24 hours.

4.15V or more

Internal Resistance

After standard charge, measure within 24 hours.

200 m max.

Capacity_1

After standard charge, measure time taken for a fast
discharge.

110 minutes or more

Charge/Discharge
Cycle

After repeating standard charge and fast discharge,
measure the fast discharge time after 300 discharge
cycles.

90 minutes or more

Capacity_2

After standard charge, measure the time taken for a
standard discharge.

500 minutes or more