5 ean 13, 6 ean 8, 5 ean 13 5.27.3.6 ean 8 – Psion Teklogix ISO 9001 User Manual
Page 192: Check digit verification, Minimum length, Field size/char, Enabled, Isbn conversion, Transmit check digit, Prefix/suffix
Chapter 5: Settings
Decoded
174
WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual
Check Digit Verification
The available options for this parameter are Disabled or French CIP. This parameter
uses the specified algorithm of the option you've chosen to ensure the integrity of
the symbol data before transmitting. If the data does not contain that algorithm, the
data is not transmitted.
Note: French CIP (French pharmaceutical) is only used with bar codes contain-
ing 7 characters.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code
refers to the number of characters (i.e., human readable characters), including
check digit(s).
Field Size/Char
Refer to page 136 for details.
5.27.3.5
EAN 13
Enabled
Set this parameter to on to enable “EAN 13”.
ISBN Conversion
When this parameter (International Standard Book Number) is enabled, the first 3
characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the
remaining characters.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Prefix/Suffix
Refer to page 138 for details.
5.27.3.6
EAN 8
Enabled
Set this parameter to on to enable “EAN 8”.