2 standard discharge, Standard discharge, Acceptance test specifications – Psion Teklogix ISO 9001 User Manual
Page 327
WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 309
Chapter 8: Specifications
Super High-Capacity (Model WA3010)
8.3.2.2
Standard Discharge
Note: Standard charge is defined as charging with constant voltage limit of 4.2V
and constant current limit of 0.9A; the termination charge occurs when
the current drops to 45mA.
Standard discharge is defined as discharging at a constant current of
350mA until the battery protection circuit switches the battery output off in
over-discharge mode.
Acceptance Test Specifications
10
Short-circuit delay time
160µs
200µs
240µs
11
Recovery charge current
0.5mA
1mA
2mA
Description
Condition
Standard
Open circuit voltage
After standard charge, measure within 24 hours.
4.15V or more
Internal Resistance
After standard charge, measure within 24 hours.
150 m max.
Capacity_1
After standard charge, measure time taken for a fast
discharge.
110 minutes or more
Charge/Discharge
Cycle
After repeating standard charge and fast discharge,
measure the fast discharge time after 300 discharge
cycles.
90 minutes or more
Capacity_2
After standard charge, measure the time taken for a
standard discharge.
500 minutes or more
Over Discharge
After standard charge, apply a standard discharge
followed by a standby discharge. Then measure
capacity after carrying out standard charge and then a
fast discharge.
110 minutes or more
Self discharge
After a standard charge, keep battery at 25°C for 30
days. Measure the time taken for a fast discharge.
100 mins or more
Temperature
Perform a standard charge and fast discharge at 0°C,
25°C and 40°C and measured the time taken for a
fast discharge at 25°C.
100 mins. @ 0°C
110 mins. @ 23°C
105 mins. @ 40°C
Item
Description
Specification