beautypg.com

2 standard discharge, Standard discharge, Acceptance test specifications – Psion Teklogix ISO 9001 User Manual

Page 327

background image

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 309

Chapter 8: Specifications

Super High-Capacity (Model WA3010)

8.3.2.2

Standard Discharge

Note: Standard charge is defined as charging with constant voltage limit of 4.2V

and constant current limit of 0.9A; the termination charge occurs when
the current drops to 45mA.

Standard discharge is defined as discharging at a constant current of
350mA until the battery protection circuit switches the battery output off in
over-discharge mode.

Acceptance Test Specifications

10

Short-circuit delay time

160µs

200µs

240µs

11

Recovery charge current

0.5mA

1mA

2mA

Description

Condition

Standard

Open circuit voltage

After standard charge, measure within 24 hours.

4.15V or more

Internal Resistance

After standard charge, measure within 24 hours.

150 m max.

Capacity_1

After standard charge, measure time taken for a fast
discharge.

110 minutes or more

Charge/Discharge
Cycle

After repeating standard charge and fast discharge,
measure the fast discharge time after 300 discharge
cycles.

90 minutes or more

Capacity_2

After standard charge, measure the time taken for a
standard discharge.

500 minutes or more

Over Discharge

After standard charge, apply a standard discharge
followed by a standby discharge. Then measure
capacity after carrying out standard charge and then a
fast discharge.

110 minutes or more

Self discharge

After a standard charge, keep battery at 25°C for 30
days. Measure the time taken for a fast discharge.

100 mins or more

Temperature

Perform a standard charge and fast discharge at 0°C,
25°C and 40°C and measured the time taken for a
fast discharge at 25°C.

100 mins. @ 0°C
110 mins. @ 23°C
105 mins. @ 40°C

Item

Description

Specification